INFUSE Multifocal
Bausch & Lomb
Base Curve:
8.6
mm
Diameter:
14.2
mm
Dk:
107
H2O:
55
%
Modulus:
0.5
MPa
CT:
.08
mm @ -3D
Extended Wear:
No
Replacement:
Daily
Material:
kalifilcon A
Propeties:
non-ionic
,
silicone hydrogel
Availability:
Available
Pricing:
Available Powers:
+6.00D to -10.00D (0.25D steps, plano included)
Initial Fitting:
+0.75D to +1.50D spectacle add
LOW ADD OU
+1.75D to +2.50D spectacle add
HIGH ADD OU
Troubleshooting
Poor Near Vision
If patient is wearing two Low Add lenses:
Replace Non-Dominant Eye with High Add.
If still unsatisfied, add +0.25D at a time to non-dominant eye (wearing High add lens).
If patient is wearing two High Add lenses:
Add +0.25D to the non-dominant eye.
If still unsatisfactory, add +0.25D at a time to non-dominant eye.
Poor Distance Vision
If patient is wearing two Low Add lenses:
Replace Dominant Eye with Single Vision lens.
If still unsatisfactory, add -0.25D at a time to dominant eye (wearing single vision lens).
If patient is wearing two High Add lenses:
Replace Dominant Eye with Low Add.
If still unsatisfactory, add -0.25D at a time to dominant eye (wearing Low Add).